Discovery - University of Dundee - Online Publications

Library & Learning Centre

A dynamic 3D foot reconstruction system

Standard

A dynamic 3D foot reconstruction system. / Thabet, Ali K.; Trucco, E.; Salvi, J.; Wang, W.; Abboud, Rami J.

Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. New York : IEEE Computer Society, 2011. p. 599-602.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Harvard

Thabet, AK, Trucco, E, Salvi, J, Wang, W & Abboud, RJ 2011, 'A dynamic 3D foot reconstruction system'. in Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. IEEE Computer Society, New York, pp. 599-602, 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society , Boston, United States, 30-3 September.

APA

Thabet, A. K., Trucco, E., Salvi, J., Wang, W., & Abboud, R. J. (2011). A dynamic 3D foot reconstruction system. In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. (pp. 599-602). New York: IEEE Computer Society. doi: 10.1109/IEMBS.2011.6090133

Vancouver

Thabet AK, Trucco E, Salvi J, Wang W, Abboud RJ. A dynamic 3D foot reconstruction system. In Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. New York: IEEE Computer Society. 2011. p. 599-602.

Author

Thabet, Ali K.; Trucco, E.; Salvi, J.; Wang, W.; Abboud, Rami J. / A dynamic 3D foot reconstruction system.

Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. New York : IEEE Computer Society, 2011. p. 599-602.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bibtex - Download

@inbook{023bb25c6c8e4880a2d1aaf6bc77c221,
title = "A dynamic 3D foot reconstruction system",
publisher = "IEEE Computer Society",
author = "Thabet, {Ali K.} and E. Trucco and J. Salvi and W. Wang and Abboud, {Rami J.}",
note = "Article number 6090133",
year = "2011",
isbn = "9781424441211",
pages = "599-602",
booktitle = "Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC",

}

RIS (suitable for import to EndNote) - Download

TY - CHAP

T1 - A dynamic 3D foot reconstruction system

A1 - Thabet,Ali K.

A1 - Trucco,E.

A1 - Salvi,J.

A1 - Wang,W.

A1 - Abboud,Rami J.

AU - Thabet,Ali K.

AU - Trucco,E.

AU - Salvi,J.

AU - Wang,W.

AU - Abboud,Rami J.

PB - IEEE Computer Society

CY - New York

PY - 2011

Y1 - 2011

N2 - <p>Foot problems are varied and range from simple disorders through to complex diseases and joint deformities. Wherever possible, the use of insoles, or orthoses, is preferred over surgery. Current insole design techniques are based on static measurements of the foot, despite the fact that orthoses are prevalently used in dynamic conditions while walking or running. This paper presents the design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion, and its use to show that foot measurements in dynamic conditions differ significantly from their static counterparts. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Engineering and clinical tests were carried out for the validation of the system. The accuracy of the system was found to be 0.34 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.44 mm (static case) and 2.81 mm (dynamic case). Furthermore, a study was performed to compare the effective length of the foot between static and dynamic reconstructions using the 4D system. Results showed an average increase of 9 mm for the dynamic case. This increase is substantial for orthotics design, cannot be captured by a static system, and its subject-specific measurement is crucial for the design of effective foot orthoses.</p>

AB - <p>Foot problems are varied and range from simple disorders through to complex diseases and joint deformities. Wherever possible, the use of insoles, or orthoses, is preferred over surgery. Current insole design techniques are based on static measurements of the foot, despite the fact that orthoses are prevalently used in dynamic conditions while walking or running. This paper presents the design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion, and its use to show that foot measurements in dynamic conditions differ significantly from their static counterparts. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Engineering and clinical tests were carried out for the validation of the system. The accuracy of the system was found to be 0.34 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.44 mm (static case) and 2.81 mm (dynamic case). Furthermore, a study was performed to compare the effective length of the foot between static and dynamic reconstructions using the 4D system. Results showed an average increase of 9 mm for the dynamic case. This increase is substantial for orthotics design, cannot be captured by a static system, and its subject-specific measurement is crucial for the design of effective foot orthoses.</p>

KW - STRUCTURED LIGHT

KW - ORTHOSES

UR - http://www.scopus.com/record/display.url?origin=recordpage&eid=2-s2.0-84055222278&noHighlight=false&sort=plf-f&src=s&st1=A+dynamic+3D+foot+reconstruction+system&sid=0721474E7BC0782D42D99C8F88821FEC.mw4ft95QGjz1tIFG9A1uw%3a160&sot=b&sdt=b&sl=54&s=TITLE-ABS-KEY%28A+dynamic+3D+foot+reconstruction+system%29&relpos=0

U2 - 10.1109/IEMBS.2011.6090133

DO - 10.1109/IEMBS.2011.6090133

M1 - Conference contribution

SN - 9781424441211

BT - Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC

T2 - Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC

SP - 599

EP - 602

ER -