Equipments Details
Description
The Dundee Cryo-EM facility hosts a JEOL JEM-2200FS electron microscope, equipped with a 200kV field emission gun (FEG) and an integrated in-column energy filter (omega filter). The microscope is currently equipped with a Gatan 4kx4k ultrascan CCD camera. As well as microscope access, we have established capability to prepare and screen samples to a high standard. We also have computing infrastructure and expertise that can be used to support the processing of datasets obtained.
Publication mapping for SLS facilities in Discovery began in 2021 and so does not include the historical contributions of the facilities in research across the University.
Publication mapping for SLS facilities in Discovery began in 2021 and so does not include the historical contributions of the facilities in research across the University.
Fingerprint
Explore the research areas in which this equipment has been used. These labels are generated based on the related outputs. Together they form a unique fingerprint.
Research output
- 3 Article
-
Structural characterisation of chromatin remodelling intermediates supports linker DNA-dependent product inhibition as a mechanism for nucleosome spacing
Hughes, A. L., Sundaramoorthy, R. (Lead / Corresponding author) & Owen-Hughes, T. (Lead / Corresponding author), 24 Dec 2025, In: eLife. p. 1-21 21 p.Research output: Contribution to journal › Article › peer-review
Open AccessFile1 Downloads (Pure) -
Targeted protein degradation via intramolecular bivalent glues
Hsia, O., Hinterndorfer, M., Cowan, A. D., Iso, K., Ishida, T., Sundaramoorthy, R., Nakasone, M. A., Imrichova, H., Schätz, C., Rukavina, A., Husnjak, K., Wegner, M., Correa-Sáez, A., Craigon, C., Casement, R., Maniaci, C., Testa, A., Kaulich, M., Dikic, I. & Winter, G. E. (Lead / Corresponding author) & 1 others, , 7 Mar 2024, In: Nature. 627, 8002, p. 204-211 8 p.Research output: Contribution to journal › Article › peer-review
Open AccessFile137 Link opens in a new tab Citations (Scopus)309 Downloads (Pure) -
The UFM1 E3 ligase recognizes and releases 60S ribosomes from ER translocons
Makhlouf, L., Peter, J. J., Magnussen, H. M., Thakur, R., Millrine, D., Minshull, T. C., Harrison, G., Varghese, J., Lamoliatte, F., Foglizzo, M., Macartney, T., Calabrese, A. N., Zeqiraj, E. (Lead / Corresponding author) & Kulathu, Y. (Lead / Corresponding author), 14 Mar 2024, In: Nature. 627, 8003, p. 437-444 8 p.Research output: Contribution to journal › Article › peer-review
Open AccessFile32 Link opens in a new tab Citations (Scopus)298 Downloads (Pure)