A novel breath-actuated integrated vortex spacer device increases relative lung bioavailability of fluticasone/salmeterol in combination

Arun Nair, Karine Clearie, Daniel Menzies, Karen Meldrum, Lesley McFarlane, Brian J. Lipworth

    Research output: Contribution to journalArticlepeer-review

    16 Citations (Scopus)

    Abstract

    Background: Spacer devices facilitate respirable drug delivery. A novel breath-actuated antistatic spacer with integrated vortex chamber (Synchro-Breathe (TM)) device has been developed, which is compact, portable and user friendly as compared to conventional spacers which are bulky and cumbersome. The relative bioavailability to the lung of inhaled fluticasone and salmeterol combination is primarily dependant on respirable dose delivery and can be reliably quantified using adrenal suppression and early fall in serum potassium (marker of systemic beta-2 adrenoreceptor response) as surrogate markers for delivered lung dose.

    Aims and objectives: To compare the in vivo relative bioavailability to the lung of Hydrofluoroalkane (HFA) Seretide (TM) delivered via Synchro-Breathe (SB); an optimally prepared 750 ml large volume plastic spacer, Volumatic (TM) (VM); and conventional Evohaler pMDI (EH).

    Methods: Nineteen healthy volunteers completed the study using a randomised double blind, double dummy crossover design. Single doses of placebo or Seretide HFA 250 (total dose ex-valve: fluticasone 2000 mcg/salmeterol 200 mcg) were administered via SB, VM and EH. Overnight urinary cortisol creatinine (OUCC) and serum potassium (K) were measured at baseline and after each dose as systemic surrogates of relative respirable dose delivery for the fluticasone and salmeterol moieties, respectively.

    Results: Significant suppression of OUCC and K occurred from baseline with SB and VM but not EH devices (geometric mean fold suppression, 95% Cl, p and arithmetic mean fall mmol/L, 95% Cl, respectively); EH: 1.51(0.43-1.01), p = 0.06: VM: 2.52(1.57-4.04), p < 0.001; SB: 2.66(1.57-4.49), p < 0.001 (equating to 33.8%, 60.2% and 62.3% falls, respectively). For K, the falls for EH were -0.09(-0.25 to 0.07), p = 0.69; VM: -0.27(-0.46 to -0.08), p = 0.003; SB: -0.32(-0.53 to -0.11), p = 0.002 (equating to 2.2%, 6.8%, and 8.06% fall, respectively). There were no significant differences between SB and VM.

    Conclusion: The breath-actuated Synchro-Breathe device was comparable to an optimally prepared Volumatic spacer, and resulted in commensurate improvement in relative lung bioavailability for both fluticasone and salmeterol moieties compared to pMDI. (C) 2009 Elsevier Ltd. All rights reserved.

    Original languageEnglish
    Pages (from-to)305-310
    Number of pages6
    JournalPulmonary Pharmacology & Therapeutics
    Volume22
    Issue number4
    DOIs
    Publication statusPublished - Aug 2009

    Keywords

    • Spacer
    • Lung bioavailability
    • Inhalers
    • Asthma
    • Seretide
    • Metered dose inhaler
    • Electrostatic charge
    • Systemic bioactivity
    • Asthmatic patients
    • Healthy subjects
    • Plastic spacers
    • Salmeterol
    • Propionate
    • Salbutamol
    • Corticosteroids

    Fingerprint

    Dive into the research topics of 'A novel breath-actuated integrated vortex spacer device increases relative lung bioavailability of fluticasone/salmeterol in combination'. Together they form a unique fingerprint.

    Cite this