A Soft Pneumatic Inchworm Double balloon (SPID) for colonoscopy

Luigi Manfredi (Lead / Corresponding author), Elisabetta Capoccia, Gastone Ciuti, Alfred Cuschieri

Research output: Contribution to journalArticle

9 Downloads (Pure)

Abstract

The design of a smart robot for colonoscopy is challenging because of the limited available space, slippery internal surfaces, and tortuous 3D shape of the human colon. Locomotion forces applied by an endoscopic robot may damage the colonic wall and/or cause pain and discomfort to patients. This study reports a Soft Pneumatic Inchworm Double balloon (SPID) mini-robot for colonoscopy consisting of two balloons connected by a 3 degrees of freedom soft pneumatic actuator. SPID has an external diameter of 18 mm, a total length of 60 mm, and weighs 10 g. The balloons provide anchorage into the colonic wall for a bio-inspired inchworm locomotion. The proposed design reduces the pressure applied to the colonic wall and consequently pain and discomfort during the procedure. The mini-robot has been tested in a deformable plastic colon phantom of similar shape and dimensions to the human anatomy, exhibiting efficient locomotion by its ability to deform and negotiate flexures and bends. The mini-robot is made of elastomer and constructed from 3D printed components, hence with low production costs essential for a disposable device
Original languageEnglish
Article number11109
Pages (from-to)1-9
Number of pages9
JournalScientific Reports
Volume9
Early online date31 Jul 2019
DOIs
Publication statusPublished - 31 Jul 2019

Fingerprint

Balloons
Pneumatics
Robots
Pneumatic actuators
Degrees of freedom (mechanics)
Elastomers
Plastics
Costs

Keywords

  • Biomedical engineering
  • Mechanical engineering
  • Physical examination
  • Polymers

Cite this

@article{8bdd6926791643f8a2b24f918c687168,
title = "A Soft Pneumatic Inchworm Double balloon (SPID) for colonoscopy",
abstract = "The design of a smart robot for colonoscopy is challenging because of the limited available space, slippery internal surfaces, and tortuous 3D shape of the human colon. Locomotion forces applied by an endoscopic robot may damage the colonic wall and/or cause pain and discomfort to patients. This study reports a Soft Pneumatic Inchworm Double balloon (SPID) mini-robot for colonoscopy consisting of two balloons connected by a 3 degrees of freedom soft pneumatic actuator. SPID has an external diameter of 18 mm, a total length of 60 mm, and weighs 10 g. The balloons provide anchorage into the colonic wall for a bio-inspired inchworm locomotion. The proposed design reduces the pressure applied to the colonic wall and consequently pain and discomfort during the procedure. The mini-robot has been tested in a deformable plastic colon phantom of similar shape and dimensions to the human anatomy, exhibiting efficient locomotion by its ability to deform and negotiate flexures and bends. The mini-robot is made of elastomer and constructed from 3D printed components, hence with low production costs essential for a disposable device",
keywords = "Biomedical engineering, Mechanical engineering, Physical examination, Polymers",
author = "Luigi Manfredi and Elisabetta Capoccia and Gastone Ciuti and Alfred Cuschieri",
year = "2019",
month = "7",
day = "31",
doi = "10.1038/s41598-019-47320-3",
language = "English",
volume = "9",
pages = "1--9",
journal = "Scientific Reports",
issn = "2045-2322",
publisher = "Nature Publishing Group",

}

A Soft Pneumatic Inchworm Double balloon (SPID) for colonoscopy. / Manfredi, Luigi (Lead / Corresponding author); Capoccia, Elisabetta; Ciuti, Gastone; Cuschieri, Alfred.

In: Scientific Reports, Vol. 9, 11109, 31.07.2019, p. 1-9.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A Soft Pneumatic Inchworm Double balloon (SPID) for colonoscopy

AU - Manfredi, Luigi

AU - Capoccia, Elisabetta

AU - Ciuti, Gastone

AU - Cuschieri, Alfred

PY - 2019/7/31

Y1 - 2019/7/31

N2 - The design of a smart robot for colonoscopy is challenging because of the limited available space, slippery internal surfaces, and tortuous 3D shape of the human colon. Locomotion forces applied by an endoscopic robot may damage the colonic wall and/or cause pain and discomfort to patients. This study reports a Soft Pneumatic Inchworm Double balloon (SPID) mini-robot for colonoscopy consisting of two balloons connected by a 3 degrees of freedom soft pneumatic actuator. SPID has an external diameter of 18 mm, a total length of 60 mm, and weighs 10 g. The balloons provide anchorage into the colonic wall for a bio-inspired inchworm locomotion. The proposed design reduces the pressure applied to the colonic wall and consequently pain and discomfort during the procedure. The mini-robot has been tested in a deformable plastic colon phantom of similar shape and dimensions to the human anatomy, exhibiting efficient locomotion by its ability to deform and negotiate flexures and bends. The mini-robot is made of elastomer and constructed from 3D printed components, hence with low production costs essential for a disposable device

AB - The design of a smart robot for colonoscopy is challenging because of the limited available space, slippery internal surfaces, and tortuous 3D shape of the human colon. Locomotion forces applied by an endoscopic robot may damage the colonic wall and/or cause pain and discomfort to patients. This study reports a Soft Pneumatic Inchworm Double balloon (SPID) mini-robot for colonoscopy consisting of two balloons connected by a 3 degrees of freedom soft pneumatic actuator. SPID has an external diameter of 18 mm, a total length of 60 mm, and weighs 10 g. The balloons provide anchorage into the colonic wall for a bio-inspired inchworm locomotion. The proposed design reduces the pressure applied to the colonic wall and consequently pain and discomfort during the procedure. The mini-robot has been tested in a deformable plastic colon phantom of similar shape and dimensions to the human anatomy, exhibiting efficient locomotion by its ability to deform and negotiate flexures and bends. The mini-robot is made of elastomer and constructed from 3D printed components, hence with low production costs essential for a disposable device

KW - Biomedical engineering

KW - Mechanical engineering

KW - Physical examination

KW - Polymers

UR - http://www.scopus.com/inward/record.url?scp=85070914043&partnerID=8YFLogxK

U2 - 10.1038/s41598-019-47320-3

DO - 10.1038/s41598-019-47320-3

M3 - Article

VL - 9

SP - 1

EP - 9

JO - Scientific Reports

JF - Scientific Reports

SN - 2045-2322

M1 - 11109

ER -