Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses

Gillian C. Leng, Mark R. Whyman, Peter T. Donnan, C. Vaughan Ruckley, Ian Gillespie, F. Gerald R. Fowkes, Paul L. Allan

Research output: Contribution to journalArticle

55 Citations (Scopus)

Abstract

Purpose: The aim of this study was to determine the accuracy of Doppler waveform characteristics in grading femoropopliteal stenoses and to determine the interobserver and intraobserver reproducibility of measuring the same waveform characteristics. Methods: Thirty patients with isolated areas of stenosis found by arteriography were evaluated by color duplex sonography. Each patient underwent scanning by two observers on two separate occasions. Each observer was blind to the other's results. Doppler spectra were recorded in areas where color change suggested the highest velocity and also at the nearest normal proximal area. Peak systolic velocity, spectral broadening, and waveform configuration were measured at each site. Results: An increase in peak systolic velocity of more than 200% accurately predicted a 50% or greater reduction in luminal diameter on angiography (70% sensitivity, 96% specificity). The presence of spectral broadening and an abnormal waveform shape were found to correlate poorly with the degree of stenosis. Analysis of variance showed no significant difference between observers in velocity measurements (p = 0.78). Conclusions: We conclude that although stenoses of greater than 50% can be distinguished from minor stenoses, more precise definition of the degree of narrowing is unlikely. The good repeatability of the velocity ratio makes it an excellent tool for monitoring major changes in the progression of disease.

Original languageEnglish
Pages (from-to)510-517
Number of pages8
JournalJournal of Vascular Surgery
Volume17
Issue number3
DOIs
Publication statusPublished - 1 Jan 1993

Fingerprint

Ultrasonography
Pathologic Constriction
Angiography
Color
Disease Progression
Analysis of Variance
Sensitivity and Specificity

Cite this

Leng, G. C., Whyman, M. R., Donnan, P. T., Ruckley, C. V., Gillespie, I., Fowkes, F. G. R., & Allan, P. L. (1993). Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. Journal of Vascular Surgery, 17(3), 510-517. https://doi.org/10.1016/0741-5214(93)90151-B
Leng, Gillian C. ; Whyman, Mark R. ; Donnan, Peter T. ; Ruckley, C. Vaughan ; Gillespie, Ian ; Fowkes, F. Gerald R. ; Allan, Paul L. / Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. In: Journal of Vascular Surgery. 1993 ; Vol. 17, No. 3. pp. 510-517.
@article{c13fe8251efd47b0a5127ffb50516968,
title = "Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses",
abstract = "Purpose: The aim of this study was to determine the accuracy of Doppler waveform characteristics in grading femoropopliteal stenoses and to determine the interobserver and intraobserver reproducibility of measuring the same waveform characteristics. Methods: Thirty patients with isolated areas of stenosis found by arteriography were evaluated by color duplex sonography. Each patient underwent scanning by two observers on two separate occasions. Each observer was blind to the other's results. Doppler spectra were recorded in areas where color change suggested the highest velocity and also at the nearest normal proximal area. Peak systolic velocity, spectral broadening, and waveform configuration were measured at each site. Results: An increase in peak systolic velocity of more than 200{\%} accurately predicted a 50{\%} or greater reduction in luminal diameter on angiography (70{\%} sensitivity, 96{\%} specificity). The presence of spectral broadening and an abnormal waveform shape were found to correlate poorly with the degree of stenosis. Analysis of variance showed no significant difference between observers in velocity measurements (p = 0.78). Conclusions: We conclude that although stenoses of greater than 50{\%} can be distinguished from minor stenoses, more precise definition of the degree of narrowing is unlikely. The good repeatability of the velocity ratio makes it an excellent tool for monitoring major changes in the progression of disease.",
author = "Leng, {Gillian C.} and Whyman, {Mark R.} and Donnan, {Peter T.} and Ruckley, {C. Vaughan} and Ian Gillespie and Fowkes, {F. Gerald R.} and Allan, {Paul L.}",
year = "1993",
month = "1",
day = "1",
doi = "10.1016/0741-5214(93)90151-B",
language = "English",
volume = "17",
pages = "510--517",
journal = "Journal of Vascular Surgery",
issn = "0741-5214",
publisher = "Elsevier",
number = "3",

}

Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. / Leng, Gillian C.; Whyman, Mark R.; Donnan, Peter T.; Ruckley, C. Vaughan; Gillespie, Ian; Fowkes, F. Gerald R.; Allan, Paul L.

In: Journal of Vascular Surgery, Vol. 17, No. 3, 01.01.1993, p. 510-517.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses

AU - Leng, Gillian C.

AU - Whyman, Mark R.

AU - Donnan, Peter T.

AU - Ruckley, C. Vaughan

AU - Gillespie, Ian

AU - Fowkes, F. Gerald R.

AU - Allan, Paul L.

PY - 1993/1/1

Y1 - 1993/1/1

N2 - Purpose: The aim of this study was to determine the accuracy of Doppler waveform characteristics in grading femoropopliteal stenoses and to determine the interobserver and intraobserver reproducibility of measuring the same waveform characteristics. Methods: Thirty patients with isolated areas of stenosis found by arteriography were evaluated by color duplex sonography. Each patient underwent scanning by two observers on two separate occasions. Each observer was blind to the other's results. Doppler spectra were recorded in areas where color change suggested the highest velocity and also at the nearest normal proximal area. Peak systolic velocity, spectral broadening, and waveform configuration were measured at each site. Results: An increase in peak systolic velocity of more than 200% accurately predicted a 50% or greater reduction in luminal diameter on angiography (70% sensitivity, 96% specificity). The presence of spectral broadening and an abnormal waveform shape were found to correlate poorly with the degree of stenosis. Analysis of variance showed no significant difference between observers in velocity measurements (p = 0.78). Conclusions: We conclude that although stenoses of greater than 50% can be distinguished from minor stenoses, more precise definition of the degree of narrowing is unlikely. The good repeatability of the velocity ratio makes it an excellent tool for monitoring major changes in the progression of disease.

AB - Purpose: The aim of this study was to determine the accuracy of Doppler waveform characteristics in grading femoropopliteal stenoses and to determine the interobserver and intraobserver reproducibility of measuring the same waveform characteristics. Methods: Thirty patients with isolated areas of stenosis found by arteriography were evaluated by color duplex sonography. Each patient underwent scanning by two observers on two separate occasions. Each observer was blind to the other's results. Doppler spectra were recorded in areas where color change suggested the highest velocity and also at the nearest normal proximal area. Peak systolic velocity, spectral broadening, and waveform configuration were measured at each site. Results: An increase in peak systolic velocity of more than 200% accurately predicted a 50% or greater reduction in luminal diameter on angiography (70% sensitivity, 96% specificity). The presence of spectral broadening and an abnormal waveform shape were found to correlate poorly with the degree of stenosis. Analysis of variance showed no significant difference between observers in velocity measurements (p = 0.78). Conclusions: We conclude that although stenoses of greater than 50% can be distinguished from minor stenoses, more precise definition of the degree of narrowing is unlikely. The good repeatability of the velocity ratio makes it an excellent tool for monitoring major changes in the progression of disease.

UR - http://www.scopus.com/inward/record.url?scp=0027536998&partnerID=8YFLogxK

U2 - 10.1016/0741-5214(93)90151-B

DO - 10.1016/0741-5214(93)90151-B

M3 - Article

VL - 17

SP - 510

EP - 517

JO - Journal of Vascular Surgery

JF - Journal of Vascular Surgery

SN - 0741-5214

IS - 3

ER -