TY - JOUR
T1 - Electrical conductance for the detection of dental caries
AU - Macey, Richard
AU - Walsh, Tanya
AU - Riley, Philip
AU - Glenny, Anne-Marie
AU - Worthington, Helen V.
AU - Clarkson, Janet E.
AU - Ricketts, David
N1 - Funding Information:
This series of Cochrane Reviews was funded by the UK National Institute for Health Research (NIHR) Cochrane Programme Grant Scheme (Project: 16/114/23). We would like to thank Anne Littlewood (Information Specialist, Cochrane Oral Health) for her advice on the search strategy and conducting the search of the literature, and Luisa M Fernandez Mauleffinch (Managing Editor and Copy Editor, Cochrane Oral Health) for her assistance in facilitating this review. We thank Associate Professor KR Ekstrand, J Bader (Emeritus Professor, UNC School of Dentistry, Chapel Hill North Carolina, USA), Iain Pretty, and Patrick Fee for their feedback on the protocol; Carlos Zaror (Faculty of Dentistry, University of La Frontera, Temuco, Chile), Jennifer Hilgart, Peter Tugwell, and the Cochrane Diagnostic Test Accuracy Editorial Team for their feedback on the review. Also Alex Sutton and Suzanne Freeman from the NIHR Complex Review Support Unit for their support on this review.
Publisher Copyright:
Copyright © 2021 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.
PY - 2021/3/16
Y1 - 2021/3/16
N2 - Background: Caries is one of the most prevalent, preventable conditions worldwide. A wide variety of management options are available at different thresholds of disease, ranging from non-operative preventive strategies such as improved oral hygiene, reduced sugar diet, and application of topical fluoride, to minimally invasive treatments for early lesions which are limited to enamel, through to selective removal and restoration for extensive lesions. The cornerstone of caries detection is a visual and tactile dental examination, however, an increasing array of methods of caries lesion detection have been proposed that could potentially support traditional methods of detection and diagnosis. Earlier identification of disease could afford patients the opportunity of less invasive treatment with less destruction of tooth tissue, reduce the need for treatment with aerosol-generating procedures, and potentially result in a reduced cost of care to the patient and to healthcare services.Objectives: Our primary objective was to determine the diagnostic accuracy of different electrical conductance devices for the detection and diagnosis of non-cavitated coronal dental caries in different populations (children, adolescents, and adults) and when tested against different reference standards.Search methods: Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 26 April 2019); Embase Ovid (1980 to 26 April 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 26 April 2019); and the World Health Organization International Clinical Trials Registry Platform (to 26 April 2019). We studied reference lists as well as published systematic review articles.Selection criteria: We included diagnostic accuracy studies that compared electrical conductance devices with a reference standard of histology or an enhanced visual examination. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. We included studies using previously extracted teeth or those that recruited participants with teeth believed to be sound or with early lesions limited to enamel.Studies that explicitly recruited participants with more advanced lesions that were obviously into dentine or frankly cavitated were excluded.Data collection and analysis: Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information was displayed as coupled forest plots, and plotted as summary receiver operating characteristic (SROC) plots, displaying the sensitivity-specificity points for each study. Due to variability in thresholds we estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods.Main results: We included seven studies reporting a total of 719 tooth sites or surfaces, with an overall prevalence of the target condition of 73% (528 tooth sites or surfaces). The included studies evaluated two index tests: the electronic caries monitor (ECM) (four studies, 475 tooth surfaces) and CarieScan Pro (three studies, 244 tooth surfaces). Six studies used histology as the reference standard, one used an enhanced visual examination. No study was considered to be at low risk of bias across all four domains or low concern for applicability or both. All studies were at high (five studies) or unclear (two studies) risk of bias for the patient selection domain. We judged two studies to be at unclear risk of bias for the index test domain, and one study to be at high risk of bias for the reference standard and flow and timing domains. We judged three studies to be at low concern for applicability for patient selection, and all seven studies to be of low concern for reference standard and flow and timing domains.Studies were synthesised using a hierarchical method for meta-analysis. There was variability in the results of the individual studies, with sensitivities which ranged from 0.55 to 0.98 and specificities from 0 to 1.00. These extreme values of specificity may be explained by a low number of healthy tooth surfaces in the included samples. The diagnostic odds ratio (DOR) was 15.65 (95% CI 1.43 to 171.15), and indicative of the variability in the included studies. Through meta-regression we observed no meaningful difference in accuracy according to device type or dentition. Due to the small number of studies we were unable to formally investigate other potential sources of heterogeneity.We judged the certainty of the evidence as very low, and downgraded for risk of bias due to limitations in the design and conduct of the included studies, imprecision arising from the relatively small number of surfaces studied, and inconsistency due to the variability of results.Authors' conclusions: The design and conduct of studies to determine the diagnostic accuracy of methods to detect and diagnose caries in situ is particularly challenging. The evidence base to support the detection and diagnosis of caries with electrical conductance devices is sparse. Newer electrical conductance devices show promise and further research at the enamel caries threshold using a robust study design to minimise bias is warranted. In terms of applicability, any future studies should be carried out in a clinical setting to provide a realistic assessment within the oral cavity where plaque, staining, and restorations can be problematic.
AB - Background: Caries is one of the most prevalent, preventable conditions worldwide. A wide variety of management options are available at different thresholds of disease, ranging from non-operative preventive strategies such as improved oral hygiene, reduced sugar diet, and application of topical fluoride, to minimally invasive treatments for early lesions which are limited to enamel, through to selective removal and restoration for extensive lesions. The cornerstone of caries detection is a visual and tactile dental examination, however, an increasing array of methods of caries lesion detection have been proposed that could potentially support traditional methods of detection and diagnosis. Earlier identification of disease could afford patients the opportunity of less invasive treatment with less destruction of tooth tissue, reduce the need for treatment with aerosol-generating procedures, and potentially result in a reduced cost of care to the patient and to healthcare services.Objectives: Our primary objective was to determine the diagnostic accuracy of different electrical conductance devices for the detection and diagnosis of non-cavitated coronal dental caries in different populations (children, adolescents, and adults) and when tested against different reference standards.Search methods: Cochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 26 April 2019); Embase Ovid (1980 to 26 April 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 26 April 2019); and the World Health Organization International Clinical Trials Registry Platform (to 26 April 2019). We studied reference lists as well as published systematic review articles.Selection criteria: We included diagnostic accuracy studies that compared electrical conductance devices with a reference standard of histology or an enhanced visual examination. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. We included studies using previously extracted teeth or those that recruited participants with teeth believed to be sound or with early lesions limited to enamel.Studies that explicitly recruited participants with more advanced lesions that were obviously into dentine or frankly cavitated were excluded.Data collection and analysis: Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information was displayed as coupled forest plots, and plotted as summary receiver operating characteristic (SROC) plots, displaying the sensitivity-specificity points for each study. Due to variability in thresholds we estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods.Main results: We included seven studies reporting a total of 719 tooth sites or surfaces, with an overall prevalence of the target condition of 73% (528 tooth sites or surfaces). The included studies evaluated two index tests: the electronic caries monitor (ECM) (four studies, 475 tooth surfaces) and CarieScan Pro (three studies, 244 tooth surfaces). Six studies used histology as the reference standard, one used an enhanced visual examination. No study was considered to be at low risk of bias across all four domains or low concern for applicability or both. All studies were at high (five studies) or unclear (two studies) risk of bias for the patient selection domain. We judged two studies to be at unclear risk of bias for the index test domain, and one study to be at high risk of bias for the reference standard and flow and timing domains. We judged three studies to be at low concern for applicability for patient selection, and all seven studies to be of low concern for reference standard and flow and timing domains.Studies were synthesised using a hierarchical method for meta-analysis. There was variability in the results of the individual studies, with sensitivities which ranged from 0.55 to 0.98 and specificities from 0 to 1.00. These extreme values of specificity may be explained by a low number of healthy tooth surfaces in the included samples. The diagnostic odds ratio (DOR) was 15.65 (95% CI 1.43 to 171.15), and indicative of the variability in the included studies. Through meta-regression we observed no meaningful difference in accuracy according to device type or dentition. Due to the small number of studies we were unable to formally investigate other potential sources of heterogeneity.We judged the certainty of the evidence as very low, and downgraded for risk of bias due to limitations in the design and conduct of the included studies, imprecision arising from the relatively small number of surfaces studied, and inconsistency due to the variability of results.Authors' conclusions: The design and conduct of studies to determine the diagnostic accuracy of methods to detect and diagnose caries in situ is particularly challenging. The evidence base to support the detection and diagnosis of caries with electrical conductance devices is sparse. Newer electrical conductance devices show promise and further research at the enamel caries threshold using a robust study design to minimise bias is warranted. In terms of applicability, any future studies should be carried out in a clinical setting to provide a realistic assessment within the oral cavity where plaque, staining, and restorations can be problematic.
U2 - 10.1002/14651858.CD014547
DO - 10.1002/14651858.CD014547
M3 - Review article
C2 - 33724442
SN - 1469-493X
VL - 2021
JO - The Cochrane database of systematic reviews
JF - The Cochrane database of systematic reviews
IS - 3
M1 - CD014547
ER -