Evaluation of six presumptive tests for blood, their specificity, sensitivity, and effect on high molecular-weight DNA

Shanan S. Tobe, Nigel Watson, Niamh Nic Daéid (Lead / Corresponding author)

Research output: Contribution to journalArticlepeer-review

184 Citations (Scopus)

Abstract

Luminol, leuchomalachite green, phenolphthalein, Hemastix®, Hemident™, and Bluestar© are all used as presumptive tests for blood. In this study, the tests were subjected to dilute blood (from 1:10,000 to 1:10,000,000), many common household substance, and chemicals. Samples were tested for DNA to determine whether the presumptive tests damaged or destroyed DNA. The DNA loci tested were D2S1338 and D19S433. Leuchomalachite green had a sensitivity of 1:10,000, while the remaining tests were able to detect blood to a dilution of 1:100,000. Substances tested include saliva, semen, potato, tomato, tomato sauce, tomato sauce with meat, red onion, red kidney bean, horseradish, 0.1 M ascorbic acid, 5% bleach, 10% cupric sulfate, 10% ferric sulfate, and 10% nickel chloride. Of all the substances tested, not one of the household items reacted with every test; however, the chemicals did. DNA was recovered and amplified from luminol, phenolphthalein, Hemastix®, and Bluestar©, but not from leuchomalachite green or Hemident™.
Original languageEnglish
Pages (from-to)102-109
Number of pages8
JournalJournal of Forensic Sciences
Volume52
Issue number1
DOIs
Publication statusPublished - Jan 2007

Fingerprint

Dive into the research topics of 'Evaluation of six presumptive tests for blood, their specificity, sensitivity, and effect on high molecular-weight DNA'. Together they form a unique fingerprint.