High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation

Research output: Chapter in Book/Report/Conference proceedingConference contribution

74 Downloads (Pure)

Abstract

High intensity focused ultrasound (HIFU) is an early stage medical technology that is in various stages of development worldwide to treat a range of disorders including skin superficial diseases. Optical coherence tomography (OCT) is a rapid development imaging technique in recent ten years, which is a good way to monitor skin because of the millimeter-level detection depth. In this study, OCT system is used to monitor the skin after HIFU treatment. A new high frequency transducer has been fabricated in this study, focal length of the transducer is super small which is suitable for the superficial diseases.

Original languageEnglish
Title of host publication2018 IEEE International Ultrasonics Symposium, IUS 2018
PublisherIEEE Computer Society
Number of pages4
Volume2018-October
ISBN (Electronic)9781538634257
DOIs
Publication statusPublished - 17 Dec 2018
Event2018 IEEE International Ultrasonics Symposium, IUS 2018 - Kobe, Japan
Duration: 22 Oct 201825 Oct 2018

Conference

Conference2018 IEEE International Ultrasonics Symposium, IUS 2018
CountryJapan
CityKobe
Period22/10/1825/10/18

Fingerprint

transducers
tomography
evaluation
imaging techniques
disorders

Keywords

  • biological optical property
  • ex-vivo bovine liver
  • ex-vivo chicken breast
  • High Intensity Focused Ultrasound (HIFU)
  • Optical Coherence Tomography (OCT)
  • treatment monitoring

Cite this

@inproceedings{2be28157514742029e6fc03180a00be1,
title = "High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation",
abstract = "High intensity focused ultrasound (HIFU) is an early stage medical technology that is in various stages of development worldwide to treat a range of disorders including skin superficial diseases. Optical coherence tomography (OCT) is a rapid development imaging technique in recent ten years, which is a good way to monitor skin because of the millimeter-level detection depth. In this study, OCT system is used to monitor the skin after HIFU treatment. A new high frequency transducer has been fabricated in this study, focal length of the transducer is super small which is suitable for the superficial diseases.",
keywords = "biological optical property, ex-vivo bovine liver, ex-vivo chicken breast, High Intensity Focused Ultrasound (HIFU), Optical Coherence Tomography (OCT), treatment monitoring",
author = "Guan Wang and Yan Wang and Kanheng Zhou and Kairui Feng and Faqi Li and Chunhui Li and Zhihong Huang",
year = "2018",
month = "12",
day = "17",
doi = "10.1109/ULTSYM.2018.8580216",
language = "English",
volume = "2018-October",
booktitle = "2018 IEEE International Ultrasonics Symposium, IUS 2018",
publisher = "IEEE Computer Society",
address = "United States",

}

Wang, G, Wang, Y, Zhou, K, Feng, K, Li, F, Li, C & Huang, Z 2018, High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation. in 2018 IEEE International Ultrasonics Symposium, IUS 2018. vol. 2018-October, 8580216, IEEE Computer Society, 2018 IEEE International Ultrasonics Symposium, IUS 2018, Kobe, Japan, 22/10/18. https://doi.org/10.1109/ULTSYM.2018.8580216

High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation. / Wang, Guan; Wang, Yan; Zhou, Kanheng; Feng, Kairui; Li, Faqi; Li, Chunhui; Huang, Zhihong.

2018 IEEE International Ultrasonics Symposium, IUS 2018. Vol. 2018-October IEEE Computer Society, 2018. 8580216.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation

AU - Wang, Guan

AU - Wang, Yan

AU - Zhou, Kanheng

AU - Feng, Kairui

AU - Li, Faqi

AU - Li, Chunhui

AU - Huang, Zhihong

PY - 2018/12/17

Y1 - 2018/12/17

N2 - High intensity focused ultrasound (HIFU) is an early stage medical technology that is in various stages of development worldwide to treat a range of disorders including skin superficial diseases. Optical coherence tomography (OCT) is a rapid development imaging technique in recent ten years, which is a good way to monitor skin because of the millimeter-level detection depth. In this study, OCT system is used to monitor the skin after HIFU treatment. A new high frequency transducer has been fabricated in this study, focal length of the transducer is super small which is suitable for the superficial diseases.

AB - High intensity focused ultrasound (HIFU) is an early stage medical technology that is in various stages of development worldwide to treat a range of disorders including skin superficial diseases. Optical coherence tomography (OCT) is a rapid development imaging technique in recent ten years, which is a good way to monitor skin because of the millimeter-level detection depth. In this study, OCT system is used to monitor the skin after HIFU treatment. A new high frequency transducer has been fabricated in this study, focal length of the transducer is super small which is suitable for the superficial diseases.

KW - biological optical property

KW - ex-vivo bovine liver

KW - ex-vivo chicken breast

KW - High Intensity Focused Ultrasound (HIFU)

KW - Optical Coherence Tomography (OCT)

KW - treatment monitoring

UR - http://www.scopus.com/inward/record.url?scp=85060573453&partnerID=8YFLogxK

U2 - 10.1109/ULTSYM.2018.8580216

DO - 10.1109/ULTSYM.2018.8580216

M3 - Conference contribution

AN - SCOPUS:85060573453

VL - 2018-October

BT - 2018 IEEE International Ultrasonics Symposium, IUS 2018

PB - IEEE Computer Society

ER -

Wang G, Wang Y, Zhou K, Feng K, Li F, Li C et al. High Intensity Focused Ultrasound (HIFU) Combines Optical Coherence Tomography(OCT) for Biological Tissue Treatment and Evaluation. In 2018 IEEE International Ultrasonics Symposium, IUS 2018. Vol. 2018-October. IEEE Computer Society. 2018. 8580216 https://doi.org/10.1109/ULTSYM.2018.8580216