TY - JOUR
T1 - Phase contrast imaging of breast tumours with synchrotron radiation
AU - Olivo, A
AU - Rigon, L
AU - Vinnicombe, S J
AU - Cheung, K C
AU - Ibison, M
AU - Speller, R D
PY - 2009
Y1 - 2009
N2 - Even though the potential of phase contrast (PC) imaging has been demonstrated in a number of biological tissue samples, the availability of free-space propagation phase contrast images of real breast tumours is still limited. The aim of this study was to obtain phase contrast images of two different pathological breast specimens containing tumours of differing morphological type at two synchrotron radiation (SR) facilities, and to assess any qualitative improvements in the evaluation and characterisation of the masses through the use of phase contrast imaging. A second aim was to assess the effects of parameters such as detector resolution, beam energy and sample-to-detector distance on image quality using the same breast specimens, as to date these effects have been modelled and discussed only for geometric phantoms. At each synchrotron radiation facility a range of images was acquired with different detectors and by varying the above parameters. Images of the same samples were also acquired with the absorption-based approach to allow a direct comparison and estimation of the advantages specifically ascribable to the PC technique.
AB - Even though the potential of phase contrast (PC) imaging has been demonstrated in a number of biological tissue samples, the availability of free-space propagation phase contrast images of real breast tumours is still limited. The aim of this study was to obtain phase contrast images of two different pathological breast specimens containing tumours of differing morphological type at two synchrotron radiation (SR) facilities, and to assess any qualitative improvements in the evaluation and characterisation of the masses through the use of phase contrast imaging. A second aim was to assess the effects of parameters such as detector resolution, beam energy and sample-to-detector distance on image quality using the same breast specimens, as to date these effects have been modelled and discussed only for geometric phantoms. At each synchrotron radiation facility a range of images was acquired with different detectors and by varying the above parameters. Images of the same samples were also acquired with the absorption-based approach to allow a direct comparison and estimation of the advantages specifically ascribable to the PC technique.
U2 - 10.1016/j.apradiso.2009.01.075
DO - 10.1016/j.apradiso.2009.01.075
M3 - Article
C2 - 19249215
SN - 1872-9800
VL - 67
SP - 1033
EP - 1041
JO - Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for use in Agriculture, Industry and Medicine
JF - Applied Radiation and Isotopes : Including Data, Instrumentation and Methods for use in Agriculture, Industry and Medicine
IS - 6
ER -