Quantitative Handheld Swept-Source Optical Coherence Tomography Angiography in Awake Preterm and Full-Term Infants

Kanheng Zhou, Shaozhen Song, Alex Legocki, Yuxuan Cheng, Leona Ding, Kasra A. Rezaei, Ruikang K. Wang, Michelle T. Cabrera (Lead / Corresponding author)

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)
8 Downloads (Pure)

Abstract

Purpose: To compare retinal vascular parameters acquired by handheld swept-source optical coherence tomography angiography (SS-OCTA) between nonsedated preterm and full-term infants.

Methods: Preterm and full-term infants at the University of Washington Medical Center were enrolled. Retinal angiograms (nominal size ∼7 × 7 mm2) were obtained at each routine retinopathy of prematurity (ROP) screening session for preterms and once during the first 72 hours of life for full-terms. Macular vessel area density and nonperfusion area were evaluated on the binarized vasculature map in both small (1.5 × 1.5 mm) and large (3 × 3 mm) quadrants. Average vessel diameter and tortuosity values were obtained from each large vessel branch (length >200 µm). All vascular analyses used previously published algorithms.

Results: Handheld SS-OCTA captured 31 of 55 (56%) high-quality volumes on 8 awake preterm infants (gestational age 28 ± 4 weeks, birth weight 891 ± 314 g, postmenstrual age at first imaging session 37 ± 2 weeks) and 48 of 54 (89%) volumes on 12 awake full-term infants (gestational age 39 ± 1 weeks, birth weight 3405 ± 329 g). Signal-to-noise ratio was 5.08 ± 1.52 dB in preterm and 4.90 ± 1.12 dB in full-term infants. Preterm infants had higher mean large vessel tortuosity compared to full-term infants (P = 0.004). The large nasal quadrant vessel area density of infants with stage 3 and/or pre-plus or worse ROP was higher than other preterm infants (P = 0.007).

Conclusions: Although inadequate image quality limited usable imaging sessions, handheld SS-OCTA achieved adequate signal-to-noise ratio in nonsedated infants for quantitative retinal vascular parameter analysis.

Translational Relevance: Large- and small-vessel parameters were associated with prematurity and ROP severity, respectively.

Original languageEnglish
Article number19
Number of pages13
JournalTranslational Vision Science and Technology
Volume9
Issue number13
DOIs
Publication statusPublished - 14 Dec 2020

Fingerprint Dive into the research topics of 'Quantitative Handheld Swept-Source Optical Coherence Tomography Angiography in Awake Preterm and Full-Term Infants'. Together they form a unique fingerprint.

Cite this