Retraction by surface ferromagnetisation of target tissues: Preliminary studies on feasibility of magnetic retraction for endoscopic surgery

Zhigang Wang, Lijun Wang, Benjie Tang, Timothy Frank, Stuart Brown, Alfred Cuschieri

    Research output: Contribution to journalArticlepeer-review

    14 Citations (Scopus)

    Abstract

    Background Magnetic retraction has potential advantages over existing direct physical retraction means (e.g., forceps) in terms of providing complete atraumatic retraction, avoiding tumour cell exfoliation as well as offering the possibility of noncontact retraction.

    This paper describes a pilot study of surface magnetic retraction of the gastric mucosa to facilitate resection.

    Methods Fifteen porcine stomach specimens were used in this pilot study. The uniaxial tensile properties of retracted mucosa were initially studied using a tensiometer. Magnetic media of ferromagnetic microparticles (stainless steel 410) dispersed in cyanoacrylate liquid were prepared at four different concentrations, and a neodymium permanent magnet was used to magnetically retract the media. The media was finally surface-glued to the target mucosa for performing a simulated surgical procedure.

    Results The force measurement data show that the retraction forces increased as the concentrations of microparticles and magnetic media volumes increased. A magnetic media concentration of 2 g/mL was most suitable since it offered sufficient retraction force from a small volume of applied media, e.g., the observed magnetic forces exerted on 50 mu L of media were 1.42 N by a 3-mm magnet and 3.75 N by a 6-mm magnet, respectively, both being more than sufficient for the mucosal retraction. The additional forces required for dissection with four alternative instruments, i.e., electrosurgery hook, snares, scalpel or scissors, were also measured, e.g., the total force required to retract up to 10 mm and resect the mucosa with snares was 0.36 +/- 0.17 N. In a simulated surgical procedure (resection of gastric mucosa with glued magnetic medium) retraction by the magnet allowed resection of the tented mucosa by an electrosurgical snare.

    Conclusion Surface ferromagnetisation of target mucosal tissues could enable magnetic retraction for endoscopic surgery.

    Original languageEnglish
    Pages (from-to)1838-1844
    Number of pages7
    JournalSurgical Endoscopy
    Volume22
    Issue number8
    DOIs
    Publication statusPublished - Aug 2008

    Keywords

    • magnetic retractionmagnetic media
    • gastric mucosa
    • magnetic force measurement
    • finite element modelling
    • ANASTOMOSIS
    • SYSTEM
    • LIVER

    Fingerprint

    Dive into the research topics of 'Retraction by surface ferromagnetisation of target tissues: Preliminary studies on feasibility of magnetic retraction for endoscopic surgery'. Together they form a unique fingerprint.

    Cite this