Abstract
This thesis developed and evaluated multimodal nanomaterial-based electrochemical and fluorescence sensing systems primarily for the rapid proof-of-concept detection and discrimination of illicit drugs in seized and related non-biological forensic samples. Human saliva was additionally included in the fluorescence-array studies as a proof-of-concept forensic-relevant biological model matrix to investigate preliminary matrix effects on analyte-dependent fluorescence responses.The research comprised two complementary sensing strands. The first integrated molecularly imprinted polymers (MIPs) with quantum dots (QDs) and QD-based nanocomposites to produce target-specific electrochemical sensors. A MnInPSeS QD-based MIP-modified screen-printed carbon electrode was developed for 3,4-methylenedioxypyrovalerone (MDPV). Using redox-probe-mediated detection, the sensor exhibited a semi-logarithmic working range of 6.0 nM to 600.0 μM, with a limit of detection of 1.26 nM and a limit of quantification of 1.63 nM. The platform also enabled probe-free electrocatalytic detection of MDPV in five illicit-drug mixtures and three of five cutting-agent mixtures. Repeatability and fabrication reusability were 3.88% and 5.97% relative standard deviation, respectively.
A second electrochemical platform, GCE/GO-MnInPtZnSe@MIP, was developed for methamphetamine using an electropolymerised MIP. Redox-probe-mediated detection produced a semi-logarithmic working range of 1-500 μM, with detection and quantification limits of 1.36 and 3.56 μM, respectively. Direct electro-oxidation produced a linear range of 1.0 μM to 10.0 mM, with corresponding detection and quantification limits of 0.76 and 2.54 μM. The sensor showed fabrication reproducibility of 3.6% relative standard deviation and was reused over four detection-elution cycles.
The second sensing mode employed cross-reactive fluorescence nanoarrays based on ligand-functionalised CdZnSe@InS QDs-GO and AgGaZnSeS QDs-Au@MnO₂ nanocomposites. Analyte-dependent fluorescence-response patterns were analysed using linear discriminant analysis, producing proof-of-concept separation of common illicit drugs and selected synthetic cathinone analogues under the experimental conditions investigated. Individually spiked human saliva samples were used to assess preliminary matrix tolerance. Although differential response patterns were retained in saliva, these findings represent exploratory matrix studies rather than validated toxicological classification. Overall, the findings demonstrate that MIP-integrated electrochemical sensors and cross-reactive fluorescence nanoarrays provide complementary nanomaterial-based strategies for presumptive forensic drug analysis. The work expands the materials-design framework for future portable sensing platforms while identifying the need for validation using authentic samples, independent datasets and established confirmatory methods.
| Date of Award | 2026 |
|---|---|
| Original language | English |
| Awarding Institution |
|
| Sponsors | Leverhulme Trust |
| Supervisor | Oluwasesan Adegoke (Supervisor) & Niamh Nic Daeid (Supervisor) |
Cite this
- Standard