Abstract
Background:RESCU is a mixed-methods observational cohort study addressing Scotland’s dramatic rise in drug-related deaths, most caused by opioid-induced respiratory depression. RESCU investigates a chest-worn accelerometer sensor’s ability to accurately capture respiratory patterns of people who use drugs (PWUD) to determine overdose response trigger points and assesses device acceptability to PWUD, third sector and first responder groups to create an intervention pathway.
Methodology:
70 participants were recruited from an injection equipment provision site in Dundee, receiving a sensor and a gateway device to record their breathing for retrospective analysis. Participants recorded their substance use and respiratory data gathered over a four-week period, returning weekly for data download.
The aim of the research was to answer the following research questions:
RQ 1. Can a chest worn accelerometer sensor dependably capture respiratory patterns of people who use drugs?
RQ 2. What are the usability and acceptability factors of wearing the respiratory sensor, particularly among people who use drugs and key stakeholders?
RQ 3. What are stakeholders’ opinions of the optimal trigger thresholds to intervene during a respiratory depression episode?
Recorded accelerometer data was analysed using developmental algorithms measuring respiratory rate and frequency and duration of apnoeic episodes.
Semi-structured interviews and focus groups were conducted with participants who engaged in the study protocol (n=21) and stakeholder groups (n=8) about device acceptability. Transcripts were analysed using Reflexive Thematic Analysis. Factors influencing device acceptability to participants were interpreted using the COM-B Model of Behaviour. Normalisation Process Theory was used to assess device integration into existing services.
Two rounds of Delphi study were run online through Jisc Online Surveys with experts view in round one (n=49) and round two (n=42) to gather and process expert consensus on alarm thresholds and escalation procedures for the PneumoWave ALERT device. Findings were further validated through focus groups with people with lived experience of drug use, which provided qualitative insights into the appropriateness and feasibility of proposed intervention strategies.
Results:
RQ 1. Can a chest worn accelerometer sensor dependably capture respiratory patterns of people who use drugs?
43 participants who returned data contributed 5,760 hours of data (2,365 hours of which were respiratory data), averaging 134 hours of data collected per each participant. Focusing on apnoeic episodes of over 30s of which there were >3 apnoeic episodes within an hour, participants experienced 851 of such apnoeic episodes, most during respiratory depression. Data review identified the presence of Biot’s respiration following consumption of opiates and benzodiazepines. No events leading to interventions occurred during monitoring.
RQ 2. What are the usability and acceptability factors of wearing the respiratory sensor, particularly among people who use drugs and key stakeholders?
Experiences with overdose or DRD were identified as motivating factors for device wear. First responders emphasised patient choice and device accuracy. Therapeutic relationships between staff and clients of the injection equipment provision site were found to be beneficial for intervention uptake.
RQ 3. What are stakeholders’ opinions of the optimal trigger thresholds to intervene during a respiratory depression episode?
The Delphi study found consensus that intervention should be triggered by either a single apnoeic episode of ≥30 seconds or three consecutive 20-second episodes, with escalation progressing from local alarms to third-party notification and finally, towards ambulance activation. Additionally, the study found strong opposition to allowing device users to adjust alarm settings themselves, due to concerns about safety. Participants also highlighted the dual value of audible alarms in prompting bystander intervention while cautioning that false alarms could strain ambulance resources.
Conclusion:
Data analysis suggests successful detection of respiratory anomalies, The evaluation highlighted positive relationships and participant choice.
| Date of Award | 2026 |
|---|---|
| Original language | English |
| Awarding Institution |
|
| Supervisor | John Dillon (Supervisor) & Andrew Radley (Supervisor) |
Keywords
- respiratory biosensor
- digital health
- process evaluation
- harm reduction
- opioid induced respiratory depression
- Qualitative Research
- quantitative research
- mixed methods study
- observational cohort study
- Dundee
- Scotland
- United Kingdom
- Substance Use
Cite this